Overview:
PCS-985 generator-transformer unit protection can be applied for turbo-dynamo, gas-turbine, hydro, pumped storage and nuclear power generator with different connection modes. It supports conventional CT/VT and ECT/EVT, and provides interfaces for power plant automation.
For medium to..
Overview:
The PCS-902 provides comprehensive protection and control solutions for transmission lines with high-speed sub-cycle distance element. The PCS-902 is intended for application on overhead lines and underground cables with diverse voltage levels. These include series compensated, double- ..
Overview:
PCS-902S line distance relay integrates main and back-up protection functions, which is designed for overhead line, cables and hybrid transmission lines of various voltage levels and provides comprehensive protection and control solutions. With its flexibility and the powerful PCS-Stud..
Overview:
The PCS-915IC centralized busbar relay provides comprehensive protection solution for various arrangements of all voltage levels. The default busbar arrangements include single busbar with/without section, double busbar with/without section, double busbar with transfer bus, breaker-and-..
Overview:
The PCS-915ID distributed busbar protection is used for protecting and monitoring various busbar arrangement with all voltage levels, including single busbar with/without section, double busbar with/without sections, double busbar with transfer bus, breaker-and-a-half arrangement and ri..
Overview:
PCS-915SD distributed busbar relay integrates busbar differential protection, bus coupler/section protection (includes overcurrent protection, switch-onto-fault protection, dead zone fault protection, dual CTs BC/BS dead zone differential protection and breaker failure protection) and f..
Overview:
The PCS-921 numerical relay provides protection for circuit breakers, which includes breaker failure protection, pole discrepancy protection, dead zone protection, phase/ negative sequence overcurrent protection, earth-fault protection, overvoltage protection, undervoltage protection, f..
Overview:
PCS-921S breaker failure relay integrates various protection functions, which is designed for the single- or three-pole circuit breaker on all voltage levels and provides comprehensive protection and control solutions. With its flexibility and the powerful PCS-Studio configuration tool,..
Overview:
The PCS-931 relay provides full-scheme current differential and distance protection solutions for transmission lines with high- speed sub-cycle distance element. As well, the pilot scheme of distance protection and earth fault protection are integrated to provide a complete protection s..
Overview:
The PCS-9611 relay is a protection, control and monitoring unit for various applications (such as overhead line, underground cable and transformer etc.) on solidly ground, impedance grounded, Peterson coil grounded and ungrounded system. The PCS-9611 features a high performance function..
Overview:
The PCS-9613 relay is a current differential protection and overcurrent protection, control and monitoring unit with auto-reclosing function for distribution feeder lines in solidly grounded, impedance grounded, Peterson coil grounded and ungrounded system.
This relay can fully suppo..
Overview:
The PCS-9631S capacitor relay is a protection, control and monitoring unit for the capacitor in all systems of which the neutral point is effectively grounded or not effectively grounded. Many auxiliary functions such as fault location, fault recording, event recording, communication fu..
Overview:
PCS-9671S has been designed specifically for the protection of various type power transformers (up to 3 measuring points), including two-winding transformers, three-winding transformers, auto-transformers, as well as shunt reactors, in 110kV voltage level and below. PCS-9671S provides t..
Overview:
The PCS-9691 relay is a protection, control and monitoring unit for various applications (such as overhead line, underground cable, transformer and capacitor etc.) on solidly grounded, impedance grounded, Peterson coil grounded and ungrounded system. The PCS-9691 features a high perform..
Overview:
The PCS-9705S Bay Control Unit (BCU) is a general-purpose control, protection and automation device in all substations, power plants and industrial domain applications. The modular conception permits the hardware adaption exact to client requirements.
The PCS-9705S is applicable not ..
Overview:
PCS-974 is a dedicated auxiliary relay for transformer nonelectrical protection. This IED provides sixteen high-powerpickup binary inputs for mechanical element monitoring, alarming and tripping. The high-power-pickup design reduces the risk of Electro-Magnetic Interference (EMI) in ord..
Overview:
PCS-978 provides full scheme protection and control solution for varies type power transformers including multiple-winding transformers and auto-transformers, as well as shunt reactors. It integrates up to 36 current/voltage inputs in order to be suitable for applications like one-and-a..
Overview:
PCS-978S transformer relay provides fast and selective protection, control and monitoring for two-winding transformers, three-winding transformers, auto-transformers, as well as shunt reactors. The full transformer protections are configurable by user. Ancillary functions of fault diagn..
Overview:
The PCS-9830 switching controller is a three-phase control device for circuit breakers it serves to open or close at specified phase angle on voltage waveform in order to minimize the impulse caused by switching on. The controlled switching technology significantly eliminates harmful el..
Overview:
PCS-985GE is a kind of high performance numerical generator protection device, which integrates main and backup protection into one device. It provides complete protection of a generator in power plant, and it also provides basic protection of a generator and an excitation transformer. ..
Overview:
The PCS-985RE is mainly designed for rotor earth fault by external voltage injection. Because of adopting self-adaptive active switching technology, The PCS-985RE can still supervise rotor insulation even if no excitation voltage is applied. It has high sensitivity and the same sensitiv..
Overview:
PCS-985TE is a kind of high performance numerical transformer protection device, which integrates main and backup protection into one device. It provides complete protection of a transformer in any voltage level, and is typically applied for startup/standby transformer or auxiliary tran..
Overview:
PCS-985TI is a high performance numerical transformer protection device, which integrates main and backup protection into one device. It provides complete protection of a transformer in any voltage level, and is typically applied for startup/standby transformer or auxiliary transformer ..
Overview:
The stator earth fault protection with external voltage injector can detect 100% earth faults in the stator windings of generator which is connected with the network via a unit transformer. The auxiliary power supply device PCS-985U can inject low-frequency external power source to the ..
Overview:
Sub-synchronous oscillations (SSO) can occur when the turbinegenerators are connected to the power grid with some electrical cases include: transmission line series capacitors, HVDC converters, large-scale wind power generation, etc. Under the action of SSO, the shaft system of turbine-..